Fulcrum Acoustic CCX826 is a passive toursound

  • Quality of the measurement data is medium.
  • Origin of the data is Fulcrum Acoustic.
  • Format of the data is a GLL file .
  • Sensitivity:
    • Measured: 101.5 dB (avg. 300Hz-3kHz for 2.83V estimated at 1m).
    • Measured: 81.5 dB computed at the measurement distance (10.0m) over the same frequency range.
  • -3dB (resp. -6db) point v.s. reference is at 109.0Hz (resp. 95.0Hz).
  • Reference level is normalised to -0.2dB computed over the frequency range [300.0Hz, 5000.0Hz].
  • Frequency deviation is 2.7dB over the same frequency range.
  • Tonality (Preference) Score
    • Note: The tonality (Preference) score does not make sense for toursound speakers. Don't give too much credits to the value.
    • Tonality (Preference) Score is 3.19 and would be 6.8 with a perfect subwoofer.
      • Details: NBD: ON 0.483, LW 0.446, SP 0.464, PIR 0.433; SM: SP0.766, PIR0.7; LFQ 2.206, LFX 100Hz
    • Tonality (Preference) Score is 4.76 with an EQ and would be 8.12 with a perfect subwoofer and the same EQ.
      • Details: NBD: ON 0.325, LW 0.287, SP 0.339, PIR 0.284; SM: SP0.899, PIR0.907; LFQ 2.24, LFX 87Hz
  • Note: Relatively high smoothing; Pattern is 120x60.
Fulcrum Acoustic CCX826
AutomaticEQ (IIR)
Set preamp gain to: -4.8dB.
Type Freq Q Gain
PK 92.0 2.65 3.0
PK 109.0 1.18 3.0
PK 125.0 2.97 -1.58
PK 190.0 0.97 -1.42
PK 3289.0 2.99 2.36
PK 11882.0 0.94 -3.98
PK 16239.0 0.36 2.98
Download
This EQ optimise the Harman score and is a good start for far field listening like in your living room.
Quick config:
Quick config:
Quick config:
;